$57.00 hourly
Bureau of Reclamation
Redding, CA, USA
Vacancy Questions Preview
Grade: 00
No questions specified.
Grade: All Grades
1 Select the response that best describes your level of experience, education, or training in troubleshooting and diagnosing technical problems of electronic/electrical equipment installed in a hydroelectric powerplant, large steam or nuclear powerplant. Answer to this question is required
I have not had education, training or experience in this task.
I have completed education or training in this task, but have not yet applied this education or training on the job.
I have journeyman-level experience in performing these tasks on the job. My work was monitored closely by a supervisor or senior journeyman employee to ensure compliance with proper procedures.
I have journeyman-level experience in performing these tasks and have performed these tasks as a regular part of my job. I have performed these tasks independently and normally without review by a supervisor or senior journeyman employee.
I have journeyman-level experience performing these tasks, which were a central or a major part of my job. I have routinely performed and have trained others in the performance of these tasks and/or others have consulted me as an expert for assistance in performing these tasks.
2 Select the response that best describes the type of powerplant facility you have worked in within the last three years. Answer to this question is required
Hydroelectric
Diesel
Gas
Steam
Nuclear
Other
None of the above
3 Select the response that best reflects how you obtained your skills as a C&I mechanic. Answer to this question is required
I have recent work experience performing routine trades/crafts tasks that required me to use standard techniques to maintain and make minor repairs to electronic equipment and power control systems, such as meters, relays, voltage regulators, governors, solid state devices, wireless communication systems, SCADA systems, etc.
I successfully completed at least a year of college or vocational technical school (30 semester units or equivalent) with courses in mathematics, engineering, electronics technology, science, or industrial technology (mechanics, machine trades, physics).
I successfully completed an associate's degree from an accredited college in electronics system technology, engineering, communication engineering, mechtronics, or closely related curriculum that included courses on electrical/electronic theoretical principles, control systems, circuitry, instrumentation, etc.
I successfully completed a technical degree program from an accredited vocational technical school (two year program or 60 semester units or equivalent) in electronics technology, control systems, communication engineering or closely related curriculum that included courses on electrical/electronic theoretical principles and practical workshop experience in instrumentation, circuitry, programmable logic controllers, digital communications, etc.
I successfully completed a bachelor's degree from an accredited college or university in engineering, electronics, control systems, communication engineering, or closely related curriculum that included courses on electrical/electronic theoretical principles, digital and wireless communications, instrumentation, circuitry, programmable logic controllers, etc.
I successfully completed an employer or military sponsored electrical/electronic training program comprised of progressively increased levels of practical and theoretical complexity. The program included on-the-job training, formal instruction or correspondence coursework that developed my skills in installing, overhauling and maintaining a variety of electronic equipment associated with protective relays, computer control systems, communication systems, and integrated electronic systems.
I successfully completed a formal apprentice program (approx. 8000 hours) recognized by the Department of Labor for C&I mechanic, electronics mechanic, electronics integrated systems mechanic or a closely related occupation. The program included on-the-job training, formal instruction or coursework at progressively increased levels of practical and theoretical complexity that developed my skills in installing, overhauling and maintaining electronic and communications equipment and systems.
I acquired C&I mechanic skills through extensive on-the-job training in a shop or industrial environment where I learned to install, troubleshoot, overhaul and maintain a variety of complete operational electronic equipment and power control systems. My assignments progressively increased in difficulty, requiring me to understand electronic theory and gain new or more advanced skills to maintain, repair and replace electronic equipment, specialized circuitry, and integrated systems.
None of the above.
4 Select the certification(s) for industrial instrumentation you possess. Answer to this question is required
NICET Level III-IV
NICET Level I-II
ISA CCST Level I-II
ISA CCST Level III
Automation Protocol Certification (e.g., HART, Fieldbus, Profibus)
Equipment Manufacturer Certification (e.g., Foxboro, Fisher, Rosemount, Honeywell)
None of the above
5 Select the computer software programs you routinely use to accomplish your work. Answer to this question is required
Doble Test Programs (any version)
SEL Protective Relay Test Programs (any version)
AVO Protective Relay Test Programs (any version)
AVTS Protective Relay Test Programs (e.g., RTS, Pulse Master, Protest, Omichron, Manta)
Documenting Instrumentation Calibration Programs (e.g., AMS, DPC, TransCal, Cornerstone)
None of the above
6 Select the response that best reflects your experience using computerized relay test equipment. Answer to this question is required
I have not had education, training or experience in performing this task.
I have completed formal education or training in performing this task but have not yet performed it on the job.
I have performed this task on the job under close supervision by a supervisor manager or senior employee to ensure compliance with correct procedures.
I have performed this task as a regular part of a job, independently and usually without review by a supervisor, manager or senior employee.
This task has been a central or major part of my work. I have performed it myself routinely, and I have trained others in performance of this task and/or others have consulted me as an expert for assistance in performing this task.
7 Select the electrical test equipment you have operated or used in a powerplant or commercial/industrial work environment. Answer to this question is required
Voltmeter.
Recording voltmeters.
Ammeters.
Ohmmeters.
Clamp-on ammeters.
Potentiometers.
Frequency meters.
Phase sequence testers.
Infrared gun or camera.
Megger.
Doble.
AC and DC High Potential (Hi-Pot) test equipment.
High current test set.
Resistance bridges.
Oscilloscopes.
Oscillographs.
Wheatstone-bridge.
Time-travel analyzer.
VAR meter.
Wattmeter.
Signal generator.
Fiber optical test equipment (fault locating, certification, losses, etc.)
Frequency counters.
Microwave link analyzer.
Insulation tester.
Logic analyzer.
Phase shifter.
Spectrum analyzer.
Phase angle meter.
Protective relaying test set.
Data breakout box.
RF frequency generator.
Transducer (MLA).
PC diagnostic equipment.
Transmission impairment measuring set.
Protocol analyzer.
RF monitors.
Signal tracers.
Data analyzers.
Wattmeter RF.
Process meter (pressure, temp, ma, etc.)
CT/PT tester.
Chart recorders (e.g. strip recorders, etc.).
None of the above.
8 Select the instrument calibration equipment you have used to accomplish your work. Answer to this question is required
Deadweight Tester
Documenting Process Calibrator
Dry Block
Loop Calibrator
Decade Box
Voltage/Current Source
Pressure Calibrator
Thermocouple/RTD Calibrator
None of the above
9 Select the response that best reflects your experience programming and testing programmable logic controllers (PLCs). Answer to this question is required
I have not had education, training or experience in performing this task.
I have completed formal education or training in performing this task but have not yet performed it on the job.
I have performed this task on the job under close supervision by a supervisor manager or senior employee to ensure compliance with correct procedures.
I have performed this task as a regular part of a job, independently and usually without review by a supervisor, manager or senior employee.
This task has been a central or major part of my work. I have performed it myself routinely, and I have trained others in performance of this task and/or others have consulted me as an expert for assistance in performing this task.
10 Select not more than three (3) of the following tasks that represent your strongest capabilities. Answer to this question is required
Calibration and maintenance of metering equipment.
Maintaining and testing battery chargers and systems.
Wiring electrical circuits.
Calibrate and test watt hour meters.
Repairing governors (solid state or digital).
Troubleshooting electrical control circuits.
Programming and troubleshooting programmable logic controllers (PLC's).
Testing instrument transformers and related circuits (polarity, ratio, burden, etc.).
Repair office equipment (faxes, copiers, etc.).
Troubleshooting voltage regulators.
Installation of new equipment or systems.
None of the above.
11 Select the response that best describes your highest level of skill in troubleshooting electronic equipment problems with instruments in a multi-unit system or particular subsystem. Answer to this question is required
I have some experience with simple troubleshooting but would need help or close supervision.
I have experience troubleshooting simple problems with normal supervision.
I have experience troubleshooting to diagnose routine common and simple problems with normal or minimal supervision.
I have experience troubleshooting to diagnose complex problems and perform complex tasks in a commercial/industrial environment with minimal supervision.
I have experience troubleshooting to diagnose complex problems and perform complex tasks with minimal or no supervision in a hydroelectric, nuclear, or steam powerplant.
None of the above
12 Select the response that best reflects your experience installing, troubleshooting, overhauling and maintaining voice and data communication equipment, such as VHF, UHF, fiber optic, and/or microwave radios. Answer to this question is required
I have not had education, training or experience in performing this task.
I have completed formal education or training in performing this task but have not yet performed it on the job.
I have performed this task on the job under close supervision by a supervisor manager or senior employee to ensure compliance with correct procedures.
I have performed this task as a regular part of a job, independently and usually without review by a supervisor, manager or senior employee.
This task has been a central or major part of my work. I have performed it myself routinely, and I have trained others in performance of this task and/or others have consulted me as an expert for assistance in performing this task.
13 Select the response that best reflects your experience installing, overhauling and maintaining supervisory control and data acquisitions (SCADA) and telemetry equipment. Answer to this question is required
I have not had education, training or experience in performing this task.
I have completed formal education or training in performing this task but have not yet performed it on the job.
I have performed this task on the job under close supervision by a supervisor manager or senior employee to ensure compliance with correct procedures.
I have performed this task as a regular part of a job, independently and usually without review by a supervisor, manager or senior employee.
This task has been a central or major part of my work. I have performed it myself routinely, and I have trained others in performance of this task and/or others have consulted me as an expert for assistance in performing this task.
14 Select the electrical and electronic equipment you have diagnosed and repaired in a powerplant or commercial/industrial work environment. Answer to this question is required
Solid state (digital) exciters.
Electro-mechanical exciters.
Solid state elevator controls.
Electro-mechanical elevator controls.
Alarm systems (Annunciator boards and controls).
Generator controls.
Generator protection.
Electrical control circuits in powerplants.
Electrical control circuits in pumping plants.
Electrical control circuits in switchyards.
Power transformers (10,000 KVA or larger).
Transformers (less than 10,000 KVA)
Circuit breakers (greater than 100 KV).
Circuit breakers (less than 100 KV but greater than 1.0 KV).
Circuit breakers (less than 1.0 KV).
Power disconnect switches.
Residential lighting switches.
Motor disconnect switches.
DC switches.
Telephone switches and equipment.
Electro-mechanical governors.
Digital governors.
AC motors.
DC motors.
Solenoid valves.
Motor controllers.
Metering equipment.
Motor operated valves.
Synchronizing equipment.
Refrigeration equipment.
Rectifiers.
Programmable logic control (PLC) equipment.
Remote terminal unit (RTU) equipment.
Sonic liquid devices.
Communications cable.
Capacitors.
Inductors.
Fiber optical cable.
Potential transformers.
Current transformers.
SCADA equipment.
Fire protection and suppression systems.
DC battery systems (including charging equipment).
AC UPS systems.
None of the above.
15 Select the response that best describes your highest level of experience, education or training in reading and interpreting manufacturer's instructions to maintain and repair electronic equipment associated with a hydroelectric powerplant facility, large steam or nuclear powerplant, or commercial/industrial communications environment. Answer to this question is required
I have not performed these job functions.
I have received post high school education or formal training in these functions, but I have not performed them on the job.
I have read and interpreted manufacturer's instructions to maintain and repair electrical equipment in an industrial maintenance facility.
I have read and interpreted manufacturer's instructions to maintain and repair electronic equipment.
I have read and interpreted manufacturer's instructions to maintain and repair electronic equipment. I am highly skilled at performing these functions. I have performed them independently and routinely.
16 Select the electrical drawings you have used to maintain and repair electrical equipment associated with a powerplant facility. Answer to this question is required
Detailed wiring diagrams.
Detailed schematic diagrams.
Manufacturer's drawings and instructions.
Electrical control diagrams.
Detailed block diagrams for circuit analysis.
Simple wiring diagrams.
Simple block diagrams.
Single line diagrams.
3-Line diagrams.
Ladder logic diagrams.
Step-by-step manufacturer's instructions.
None of the above.
17 Select the response that best describes your highest level of skill using electrical and electronic schematic drawings specific to hydroelectric powerplant systems. Answer to this question is required
I have used schematic drawings but would need help interpreting them or close supervision.
I have used schematic drawings to perform common and simple tasks with normal supervision.
I have used schematic drawings to diagnose routine common and simple tasks with normal or minimal supervision.
I have used schematic drawings to diagnose complex problems and perform complex tasks with minimal supervision.
I have used schematic drawings to diagnose complex problems and perform complex tasks with minimal or no supervision and have used these diagrams to instruct others.
None of the above.
18 I am familiar with and have performed job duties under the guidelines of the U.S. Bureau of Reclamation's Facilities, Instructions, Standards, and Techniques (FIST), Volume 1-1 (Hazardous Energy Control Program) Manual or equivalent OSHA lockout/tagout (LOTO) regulations. Answer to this question is required
Yes
No
19 Select the response that defines how many at-fault accidents (personal injury to self or others, or property damage) you have had at work in the past ten years. Answer to this question is required
No more than one (1).
No more than two (2).
More than two but less than six (6).
Six or more (but less than ten (10)).
Ten (10) or more.
I have never had an at-fault accident at work.
20 I have performed electrical maintenance on equipment at heights exceeding 60 feet. Answer to this question is required
Yes
No
21 Are you physically able to perform work involving confined space entry and working in confined quarters? Answer to this question is required
Yes
No
22 Are you physically able to lift items weighing up to 50 pounds on a regular basis? Answer to this question is required
Yes
No
23 This position may require considerable physical effort in walking, climbing, stooping, and bending; work in temperatures that fluctuate from extreme cold to extreme heat, and in wet and or windy conditions. Are you able to work under these conditions? Answer to this question is required
Yes
No
24 Have you received an employee performance appraisal rating in the previous 12 months?
Yes
No
25 Indicate who officially rated your performance (e.g., immediate supervisor, 2nd level supervisor, acting supervisor, etc.). Also, indicate your rating in terms of the performance system (e.g., 3 level rating out of a 5-tier system; 2 level rating out of a 3-tier system; Pass rating out of a Pass/Fail system). Maximum length of 250 characters.
26 In the last three years, have you been recognized for your performance, accomplishments, and/or contributions at work?
Yes
No
Gary Munson
Celeste Swanson,
cbswanson@usbr.gov
Vacancy Questions Preview
Grade: 00
No questions specified.
Grade: All Grades
1 Select the response that best describes your level of experience, education, or training in troubleshooting and diagnosing technical problems of electronic/electrical equipment installed in a hydroelectric powerplant, large steam or nuclear powerplant. Answer to this question is required
I have not had education, training or experience in this task.
I have completed education or training in this task, but have not yet applied this education or training on the job.
I have journeyman-level experience in performing these tasks on the job. My work was monitored closely by a supervisor or senior journeyman employee to ensure compliance with proper procedures.
I have journeyman-level experience in performing these tasks and have performed these tasks as a regular part of my job. I have performed these tasks independently and normally without review by a supervisor or senior journeyman employee.
I have journeyman-level experience performing these tasks, which were a central or a major part of my job. I have routinely performed and have trained others in the performance of these tasks and/or others have consulted me as an expert for assistance in performing these tasks.
2 Select the response that best describes the type of powerplant facility you have worked in within the last three years. Answer to this question is required
Hydroelectric
Diesel
Gas
Steam
Nuclear
Other
None of the above
3 Select the response that best reflects how you obtained your skills as a C&I mechanic. Answer to this question is required
I have recent work experience performing routine trades/crafts tasks that required me to use standard techniques to maintain and make minor repairs to electronic equipment and power control systems, such as meters, relays, voltage regulators, governors, solid state devices, wireless communication systems, SCADA systems, etc.
I successfully completed at least a year of college or vocational technical school (30 semester units or equivalent) with courses in mathematics, engineering, electronics technology, science, or industrial technology (mechanics, machine trades, physics).
I successfully completed an associate's degree from an accredited college in electronics system technology, engineering, communication engineering, mechtronics, or closely related curriculum that included courses on electrical/electronic theoretical principles, control systems, circuitry, instrumentation, etc.
I successfully completed a technical degree program from an accredited vocational technical school (two year program or 60 semester units or equivalent) in electronics technology, control systems, communication engineering or closely related curriculum that included courses on electrical/electronic theoretical principles and practical workshop experience in instrumentation, circuitry, programmable logic controllers, digital communications, etc.
I successfully completed a bachelor's degree from an accredited college or university in engineering, electronics, control systems, communication engineering, or closely related curriculum that included courses on electrical/electronic theoretical principles, digital and wireless communications, instrumentation, circuitry, programmable logic controllers, etc.
I successfully completed an employer or military sponsored electrical/electronic training program comprised of progressively increased levels of practical and theoretical complexity. The program included on-the-job training, formal instruction or correspondence coursework that developed my skills in installing, overhauling and maintaining a variety of electronic equipment associated with protective relays, computer control systems, communication systems, and integrated electronic systems.
I successfully completed a formal apprentice program (approx. 8000 hours) recognized by the Department of Labor for C&I mechanic, electronics mechanic, electronics integrated systems mechanic or a closely related occupation. The program included on-the-job training, formal instruction or coursework at progressively increased levels of practical and theoretical complexity that developed my skills in installing, overhauling and maintaining electronic and communications equipment and systems.
I acquired C&I mechanic skills through extensive on-the-job training in a shop or industrial environment where I learned to install, troubleshoot, overhaul and maintain a variety of complete operational electronic equipment and power control systems. My assignments progressively increased in difficulty, requiring me to understand electronic theory and gain new or more advanced skills to maintain, repair and replace electronic equipment, specialized circuitry, and integrated systems.
None of the above.
4 Select the certification(s) for industrial instrumentation you possess. Answer to this question is required
NICET Level III-IV
NICET Level I-II
ISA CCST Level I-II
ISA CCST Level III
Automation Protocol Certification (e.g., HART, Fieldbus, Profibus)
Equipment Manufacturer Certification (e.g., Foxboro, Fisher, Rosemount, Honeywell)
None of the above
5 Select the computer software programs you routinely use to accomplish your work. Answer to this question is required
Doble Test Programs (any version)
SEL Protective Relay Test Programs (any version)
AVO Protective Relay Test Programs (any version)
AVTS Protective Relay Test Programs (e.g., RTS, Pulse Master, Protest, Omichron, Manta)
Documenting Instrumentation Calibration Programs (e.g., AMS, DPC, TransCal, Cornerstone)
None of the above
6 Select the response that best reflects your experience using computerized relay test equipment. Answer to this question is required
I have not had education, training or experience in performing this task.
I have completed formal education or training in performing this task but have not yet performed it on the job.
I have performed this task on the job under close supervision by a supervisor manager or senior employee to ensure compliance with correct procedures.
I have performed this task as a regular part of a job, independently and usually without review by a supervisor, manager or senior employee.
This task has been a central or major part of my work. I have performed it myself routinely, and I have trained others in performance of this task and/or others have consulted me as an expert for assistance in performing this task.
7 Select the electrical test equipment you have operated or used in a powerplant or commercial/industrial work environment. Answer to this question is required
Voltmeter.
Recording voltmeters.
Ammeters.
Ohmmeters.
Clamp-on ammeters.
Potentiometers.
Frequency meters.
Phase sequence testers.
Infrared gun or camera.
Megger.
Doble.
AC and DC High Potential (Hi-Pot) test equipment.
High current test set.
Resistance bridges.
Oscilloscopes.
Oscillographs.
Wheatstone-bridge.
Time-travel analyzer.
VAR meter.
Wattmeter.
Signal generator.
Fiber optical test equipment (fault locating, certification, losses, etc.)
Frequency counters.
Microwave link analyzer.
Insulation tester.
Logic analyzer.
Phase shifter.
Spectrum analyzer.
Phase angle meter.
Protective relaying test set.
Data breakout box.
RF frequency generator.
Transducer (MLA).
PC diagnostic equipment.
Transmission impairment measuring set.
Protocol analyzer.
RF monitors.
Signal tracers.
Data analyzers.
Wattmeter RF.
Process meter (pressure, temp, ma, etc.)
CT/PT tester.
Chart recorders (e.g. strip recorders, etc.).
None of the above.
8 Select the instrument calibration equipment you have used to accomplish your work. Answer to this question is required
Deadweight Tester
Documenting Process Calibrator
Dry Block
Loop Calibrator
Decade Box
Voltage/Current Source
Pressure Calibrator
Thermocouple/RTD Calibrator
None of the above
9 Select the response that best reflects your experience programming and testing programmable logic controllers (PLCs). Answer to this question is required
I have not had education, training or experience in performing this task.
I have completed formal education or training in performing this task but have not yet performed it on the job.
I have performed this task on the job under close supervision by a supervisor manager or senior employee to ensure compliance with correct procedures.
I have performed this task as a regular part of a job, independently and usually without review by a supervisor, manager or senior employee.
This task has been a central or major part of my work. I have performed it myself routinely, and I have trained others in performance of this task and/or others have consulted me as an expert for assistance in performing this task.
10 Select not more than three (3) of the following tasks that represent your strongest capabilities. Answer to this question is required
Calibration and maintenance of metering equipment.
Maintaining and testing battery chargers and systems.
Wiring electrical circuits.
Calibrate and test watt hour meters.
Repairing governors (solid state or digital).
Troubleshooting electrical control circuits.
Programming and troubleshooting programmable logic controllers (PLC's).
Testing instrument transformers and related circuits (polarity, ratio, burden, etc.).
Repair office equipment (faxes, copiers, etc.).
Troubleshooting voltage regulators.
Installation of new equipment or systems.
None of the above.
11 Select the response that best describes your highest level of skill in troubleshooting electronic equipment problems with instruments in a multi-unit system or particular subsystem. Answer to this question is required
I have some experience with simple troubleshooting but would need help or close supervision.
I have experience troubleshooting simple problems with normal supervision.
I have experience troubleshooting to diagnose routine common and simple problems with normal or minimal supervision.
I have experience troubleshooting to diagnose complex problems and perform complex tasks in a commercial/industrial environment with minimal supervision.
I have experience troubleshooting to diagnose complex problems and perform complex tasks with minimal or no supervision in a hydroelectric, nuclear, or steam powerplant.
None of the above
12 Select the response that best reflects your experience installing, troubleshooting, overhauling and maintaining voice and data communication equipment, such as VHF, UHF, fiber optic, and/or microwave radios. Answer to this question is required
I have not had education, training or experience in performing this task.
I have completed formal education or training in performing this task but have not yet performed it on the job.
I have performed this task on the job under close supervision by a supervisor manager or senior employee to ensure compliance with correct procedures.
I have performed this task as a regular part of a job, independently and usually without review by a supervisor, manager or senior employee.
This task has been a central or major part of my work. I have performed it myself routinely, and I have trained others in performance of this task and/or others have consulted me as an expert for assistance in performing this task.
13 Select the response that best reflects your experience installing, overhauling and maintaining supervisory control and data acquisitions (SCADA) and telemetry equipment. Answer to this question is required
I have not had education, training or experience in performing this task.
I have completed formal education or training in performing this task but have not yet performed it on the job.
I have performed this task on the job under close supervision by a supervisor manager or senior employee to ensure compliance with correct procedures.
I have performed this task as a regular part of a job, independently and usually without review by a supervisor, manager or senior employee.
This task has been a central or major part of my work. I have performed it myself routinely, and I have trained others in performance of this task and/or others have consulted me as an expert for assistance in performing this task.
14 Select the electrical and electronic equipment you have diagnosed and repaired in a powerplant or commercial/industrial work environment. Answer to this question is required
Solid state (digital) exciters.
Electro-mechanical exciters.
Solid state elevator controls.
Electro-mechanical elevator controls.
Alarm systems (Annunciator boards and controls).
Generator controls.
Generator protection.
Electrical control circuits in powerplants.
Electrical control circuits in pumping plants.
Electrical control circuits in switchyards.
Power transformers (10,000 KVA or larger).
Transformers (less than 10,000 KVA)
Circuit breakers (greater than 100 KV).
Circuit breakers (less than 100 KV but greater than 1.0 KV).
Circuit breakers (less than 1.0 KV).
Power disconnect switches.
Residential lighting switches.
Motor disconnect switches.
DC switches.
Telephone switches and equipment.
Electro-mechanical governors.
Digital governors.
AC motors.
DC motors.
Solenoid valves.
Motor controllers.
Metering equipment.
Motor operated valves.
Synchronizing equipment.
Refrigeration equipment.
Rectifiers.
Programmable logic control (PLC) equipment.
Remote terminal unit (RTU) equipment.
Sonic liquid devices.
Communications cable.
Capacitors.
Inductors.
Fiber optical cable.
Potential transformers.
Current transformers.
SCADA equipment.
Fire protection and suppression systems.
DC battery systems (including charging equipment).
AC UPS systems.
None of the above.
15 Select the response that best describes your highest level of experience, education or training in reading and interpreting manufacturer's instructions to maintain and repair electronic equipment associated with a hydroelectric powerplant facility, large steam or nuclear powerplant, or commercial/industrial communications environment. Answer to this question is required
I have not performed these job functions.
I have received post high school education or formal training in these functions, but I have not performed them on the job.
I have read and interpreted manufacturer's instructions to maintain and repair electrical equipment in an industrial maintenance facility.
I have read and interpreted manufacturer's instructions to maintain and repair electronic equipment.
I have read and interpreted manufacturer's instructions to maintain and repair electronic equipment. I am highly skilled at performing these functions. I have performed them independently and routinely.
16 Select the electrical drawings you have used to maintain and repair electrical equipment associated with a powerplant facility. Answer to this question is required
Detailed wiring diagrams.
Detailed schematic diagrams.
Manufacturer's drawings and instructions.
Electrical control diagrams.
Detailed block diagrams for circuit analysis.
Simple wiring diagrams.
Simple block diagrams.
Single line diagrams.
3-Line diagrams.
Ladder logic diagrams.
Step-by-step manufacturer's instructions.
None of the above.
17 Select the response that best describes your highest level of skill using electrical and electronic schematic drawings specific to hydroelectric powerplant systems. Answer to this question is required
I have used schematic drawings but would need help interpreting them or close supervision.
I have used schematic drawings to perform common and simple tasks with normal supervision.
I have used schematic drawings to diagnose routine common and simple tasks with normal or minimal supervision.
I have used schematic drawings to diagnose complex problems and perform complex tasks with minimal supervision.
I have used schematic drawings to diagnose complex problems and perform complex tasks with minimal or no supervision and have used these diagrams to instruct others.
None of the above.
18 I am familiar with and have performed job duties under the guidelines of the U.S. Bureau of Reclamation's Facilities, Instructions, Standards, and Techniques (FIST), Volume 1-1 (Hazardous Energy Control Program) Manual or equivalent OSHA lockout/tagout (LOTO) regulations. Answer to this question is required
Yes
No
19 Select the response that defines how many at-fault accidents (personal injury to self or others, or property damage) you have had at work in the past ten years. Answer to this question is required
No more than one (1).
No more than two (2).
More than two but less than six (6).
Six or more (but less than ten (10)).
Ten (10) or more.
I have never had an at-fault accident at work.
20 I have performed electrical maintenance on equipment at heights exceeding 60 feet. Answer to this question is required
Yes
No
21 Are you physically able to perform work involving confined space entry and working in confined quarters? Answer to this question is required
Yes
No
22 Are you physically able to lift items weighing up to 50 pounds on a regular basis? Answer to this question is required
Yes
No
23 This position may require considerable physical effort in walking, climbing, stooping, and bending; work in temperatures that fluctuate from extreme cold to extreme heat, and in wet and or windy conditions. Are you able to work under these conditions? Answer to this question is required
Yes
No
24 Have you received an employee performance appraisal rating in the previous 12 months?
Yes
No
25 Indicate who officially rated your performance (e.g., immediate supervisor, 2nd level supervisor, acting supervisor, etc.). Also, indicate your rating in terms of the performance system (e.g., 3 level rating out of a 5-tier system; 2 level rating out of a 3-tier system; Pass rating out of a Pass/Fail system). Maximum length of 250 characters.
26 In the last three years, have you been recognized for your performance, accomplishments, and/or contributions at work?
Yes
No
Gary Munson
Celeste Swanson,
cbswanson@usbr.gov